Specifications
Sensor Characteristics
Average Power
Frequency Range 350 MHz to 4 GHz
RF Power Range 0.15 W – 150 W Average, 4 – 400 W Peak
Maximum Power See Figure 7 on page 9
Impedance, Nominal 50 ohms
Insertion Loss, Max:
0.35 – 1 GHz
1 – 4 GHz
0.05 dB
0.1 dB
Input VSWR, Max:
0.35 – 2.5 GHz
2.5 – 4 GHz
1.05:1
1.10:1
Directivity, Min:
0.35 – 3 GHz
3 – 4 GHz
30 dB
28 dB
RF Connectors N Female
Interface:
DPM
PC Serial Port
PC USB Port
Male DB-9, EIA-232, 9600 Baud, no
parity, 8 data bits, 1 stop bit
Female DB-9, EIA-232, 9600 Baud, no
parity, 8 data bits, 1 stop bit
USB 1.1 interface
Power Supply:
DPM
USB Port
DC Connector
From host instrument via cable
less than one low-power USB load
7 – 18 Vdc, < 100 mA
RF Power Range 2 – 150 W
RF Power Range 0.15 – 2 W
Peak/Average Ratio, Max 12 dB
Measurement Uncert. ± (4% of reading)
*
* Above 35 °C or below 15 °C add 3%
Measurement Uncert. ± (7% of reading ± 0.05 W)*